How to configure your RedVision Battery Protection
Battery Protect is designed to prevent excessive discharge of the auxiliary battery. Learn how to configure your RedVision's Battery Protect setting here. For more information refer to the RedVision user manual.
This information is applicable to the following products:
- TVMS Rogue (TVMS1240)
- TVMS Prime (TVMS1280)
- Tap Load Disconnect from the main screen.
- Tap Battery Protect.


Ensure Battery Protect is Enabled.
Adjust the minimum voltage that all the channels will switch off at.
Tap Save.


Under the Product Load Disconnect Settings heading, tap Charger (Manager).
In battery management systems, the load disconnect feature automatically disconnects non-essential loads when the battery reaches a predetermined value, such as a Voltage or State of Charge (SoC). This prevents excessive discharge of the house battery, ensuring that essential loads, like a refrigerator, can continue running for a longer period while managing available input power.
Set the Disconnect Type.
The list below provides the disconnect type options.
Always: overrides the load disconnect feature.
Voltage: uses the battery voltage information to enable/disable Load Disconnect based on turn ON/OFF voltage thresholds.
BMS Voltage: uses the Manager battery voltage information to enable/disable Load Disconnect based on turn ON/OFF voltage thresholds.
BMS SOC: uses the Manager battery percentage information to enable/disable Load Disconnect based on turn ON/OFF percentage thresholds.
Never: disables the load disconnect feature.


For applications using Manager30 or Manager Alpha, the suggested Disconnect Type is BMS SOC, this refers to the Battery Percentage that you see on the home screen of the RedVision Display and RedVision App. For all other applications, set Disconnect Type to Always, which will override the load disconnect feature.
Tap BMS SOC as Disconnect Type.
For Lead Acid or AGM Batteries; Adjust Falls Bellow to 50% and Turn Back On Above to 55%
For Lithium Batteries; Adjust Falls Bellow to 20% and Turn Back On Above to 25%
Much like the Manager Charger Disconnect Trigger.
Tap save.
Tap Back until you are back at the main screen.


To view or download the full RedVision Configuration Guide, click here.