How to configure your TVMS Rogue
If your RedVision system contains a TVMS Rogue please follow the configuration guide below.
This information is applicable to the following products:
- TVMS Rogue (TVMS1240)
Please note: If you are adding a TVMS Rogue to an already configured system, you will need to Read Device and connect to your system before completing the instructions below. If an Output doesn’t have any installed accessories, leave the Output disabled.
Under the TVMS Modules heading, tap Wiring Configuration.
Tap TVMS Rogue.


Under Module Name, if multiple TVMS Modules (Rogue or Prime) are installed, rename each TVMS module for easier identification.
Tap Outputs.
To configure Outputs C1-C5 and D1-D5.
Tap one of the Outputs that has installed accessories.


Add a Label.
Set an Icon for the output.


Next, set the output to User Controlled or Always On.
User Controlled will enable on/off operation when using the soft keys on the RedVision display or RedVision App.
Always On will lock the output for constant power to the accessory.
If the accessory connected to this output is a dimmable LED, you can toggle on Enable Light Dimming Mode.
Set Master Switched from Display on or off.
Turning on will allow multi-channel on/off control when using the Master Switch. The Master Switch function can be accessed by double tapping the power button on either the RedVision Display or RedVision App.
Tap Save.


Repeat this process for the remaining Outputs that have installed accessories.


Tap Back.
If you have a sensor(s) installed to the Rogue, follow the instructions below:
If a Sensor Input doesn’t have a sensor(s) installed, leave the Sensor Input disabled.
Tap Sensor Inputs.
The Rogue has 2 configurable Analog Sensor Inputs (Generic Analog Input 1 and Generic Analog Input 2) and a Voltage Input.
There is additional monitoring of the input voltage to the Rogue which can be enabled if required.
Tap one of the Inputs that has installed sensors.


Set the Sensor Type.


If Fluid Tank Level is selected;
Ensure Sensor Input is Enabled.
Add a Label.
Set the Fluid Type.
Optional: Set Widget Overlay (eg: 1 for Tank 1 or G for Grey Water).


Set Sensor Type.
REDARC has 3 different length float sensors. Third party float sensors can be configured by selecting Custom in the Sensor Type drop down.
If a custom tank sensor is used, you will need to program the water levels by entering either resistance or voltage values.
Add additional reference points by tapping Add.
Set Alarm Type, if necessary.
The alarm will appear as a warning on the RedVision Display once the specified Fluid Tank Level percentage limit is reached.
Tap Save.


If Temperature is selected;
Ensure Sensor Input is Enabled.
Add a Label.
Set an Icon.
Set a Sensor.
Set Alarm Type, if necessary.
The alarm will appear as a warning on the RedVision Display once the specified Temperature limit is reached.
Tap Save.


If Voltage is selected;
Ensure Sensor Input is Enabled.
Add a Label.
Set an Icon.
Set Alarm Type, if necessary.
The alarm will appear as a warning on the RedVision Display once the specified Voltage limit is reached.
Tap Save.


Repeat this process for the remaining Sensor Inputs that have installed sensors.
When complete, tap Back.


If you have installed physical switches to the Rogue, follow the instructions below:
If a Switch Input doesn’t have any physical switches installed, leave the Switch Input disabled.
Tap Switch Inputs.
The Rogue allows up to 8 Switch Inputs either for mechanical switches or signals.
Tap one of the Switch Inputs that is connected to a physical switch.


Add a Label.
Set an Icon.
Set either a Mechanical Switch type or Signal type.
Signals can be used to turn output channels on or off when voltage is applied. For example, allowing motion sensor to activate lighting circuits or triggering reverse lights.
Tap Save.


Repeat this process for the remaining Switch Inputs that are connected to a physical switch.
When complete, tap Back until you are back at the main screen.


Tap Output Groups.
Output Groups allows the control of multiple
Output Channels from one switch or input.
Tap Add Group.


Add a Group Name.
Set an Icon.
Tap Modify Group Channels.


Select all the Channels (outputs) you wish to group together.
The most common channels (outputs) to group are lighting outputs.
Tap Save.
Tap Save.
Tap Back until you are back at the main screen.


Tap Control Configuration.
Control Configuration allows you to assign an output to a Switch Action.
Tap one of the Switch Inputs to assign an output or output group.


Tap Choose Output or Group.
Tap an Output Group or a single TVMS Rogue Output to assign to the Switch Input.


Under Control Logic, set your control type.
Toggle: Is the default, on/off operation.
Dimmer: Allows for toggling on/off and press and hold for dimming. Suitable for dimmable LED circuits.
Control Parameters: Allows the percentage of dimming to be set for when the LED is switched on, adjustable from 0-100%
Timer: Allows for the channel to be switched on for a specific time.
Control Parameters: Allows the channel to remain on for up to 23hrs 59mins 59secs
Bell Press: Allows the channel to be active when the switch is held down.
Lock Off: Locks a particular channel or channels off when the switch is active.
Control Parameters: allows the channel to return to its initial state when the switch is inactive
Lock On: Locks a particular channel or channels on when the switch is active.
Control Parameters: allows the channel to return to its initial state when the switch is inactive
Tap Save.
Tap Back until you are back at the main screen.
Repeat this process for the remaining Switch Actions to assign an output or output group.


To view or download the full RedVision Configuration guide, click here.